The day a loose screw in a King Air panel cost me 6 hours and a lot of pride
Last Tuesday I spent 6 hours chasing an intermittent avionics flicker on a King Air 200 in Grand Rapids and it turned out to be a loose ground screw behind the glare shield. I had swapped two connectors and pulled half the panel before I thought to check the grounds. The shop lead walked over, put a meter on it for ten seconds, and said "start at the frame, not the box." Felt dumb but I won't forget that order of checks anytime soon. What's your go to first move when an electrical gremlin shows up mid shift?