The signal man in Baytown waved me down mid pick and told me my load chart was for the wrong boom length
Last Thursday I was setting a 4,200 lb HVAC unit on a roof in Baytown and the signal man stopped me halfway up. He walked over, looked at the boom angle indicator, and asked what length I was running. I had punched in the chart for 110 ft but the boom was at 95. He just pointed at the chart on my cab wall and said, "you're reading the wrong row, chief." We landed it fine but I sat there for a minute after feeling like a rookie. He had 22 years on me and caught it from 80 feet away. How do you guys double check your chart on a pick you've run a hundred times?